2026 CDN Price List_R9 - Flipbook - Page 22
MAGNETIC LOCKS
LOCKING PRODUCTS
CX-DE1200 SERIES: DELAYED
EGRESS MAGNETIC LOCKS
CX-DE1200 Series delayed egress magnetic locks feature heavy-duty construction,
1,200 lbs. holding force and a range of models. Field selectable operation for
varied applications, including retail, institutional, or healthcare buildings.
Building & Fire Life
Safety Code Compliant:
Delayed egress magnetic locks are UL and ULC listed and there is a selection of
models factory con昀椀gured to meet the code requirements of all jurisdictions
in North America. The CX-DE1200 is supported with a tandem maglock for
double doors, and a full complement of ancillary devices, including key switches,
annunciators, and signal appliances.
IBC International Building Code
NFPA 101 Life Safety Code
NFPA 1, UFC Uniform Fire Code
CBC California Building Code
BOCA National Building Code
Chicago Building Code
UL 294
ULC S533
Speci昀椀cations
Features
• Auto sensing voltage power input
12/24 VDC
Voltage: 12/24 VDC +/- 10% (Auto Sensing)
• Holding force up to 1,200 lbs.
• Field selectable exit delay time 15 /30 seconds
• Power polarity protection
Lock Status Relay Rating Max: 30 VDC, 2A
• Nuisance delay period either 1, 2, or 3 seconds
• Optional connection for
auxiliary lock (double leaf door)
Alarm Output Rating Max: 30 VDC, 2A
• 75dB voice alerts with led segment
bar displaying countdown time & field
selectable languages
DPS Rating:
• Hall effect sensor monitoring output
• Door position status & bond status
• Remote reset and bypass via keyswitch
• Automatic / manual start-up on power restore
• Single gang 90dB sounder provided for
alarm alerts
Current Draw:
600mA / 330mA
Max. 30 VDC, 0.1A
Bond Sensor Rating: Max. CX-DE1200: 30 VDC, 2A
• Anti-tamper status
ATS Rating:
• Tailgating prevention door will re-lock as soon as it closes
Holding Force:
Up to 1,200 lbs. (544 kg.)
• Anti-pass back/auto re-lock:
If door doesn't open after the count
down, the door will automatically
re-lock
Operating Temp:
0~55°C (32~131°F)
Dimensions: Lock: 3"H x 11"W x 3"D
(76mm x 280mm x 76mm)
30 VAC / 42.4 VDC, 5A (Max.)
Armature Plate: 2-5/8"H x 11"W x 1"D
(68mm x 280mm x 23.5mm)
DELAYED EGRESS MAGNETIC LOCK OPERATION
Delayed egress magnetic locks are available in a range of factory default operating modes. Select the model for your application
based upon the NFPA, BOCA, and operation requirements of your local authority having jurisdiction.
DELAY RELEASE TIME (SECONDS)
MODELS
FIXED
CX-DE1200/1220-N1
NUISANCE DELAY (SECONDS)
SELECTABLE
FIXED
15 or 30
FIXED
SELECTABLE
LOCK STATUS ON POWER-UP
FIXED
SELECTABLE
1 or 2
Manual
Locked / Unlocked
CX-DE1200/1220-N2
15
0 or 1
Manual
Locked / Unlocked
CX-DE1200/1220-N3
30
0 or 1
Manual
Locked / Unlocked
CX-DE1200/1220-N4
15
0 or 1
Manual
CX-DE1200/1220-B1
15
0 or 3
Auto / Manual
Locked / Unlocked
CX-DE1200/1220-B2
30
0 or 3
Auto / Manual
Locked / Unlocked
CX-DE1200/1220-B3
15
Auto / Manual
Locked / Unlocked
0
N# = NFPA COMPLIANCE
20
SELECTABLE
RESET AFTER ALARM
2026
|
LIST PRICE IN CDN DOLLARS
B # = BOCA COMPLIANCE
Unlocked